- Home /
- BIM Library /
- All Model Groups /
- In Plant Offices /
- 8' x 20' In Plant Office
Family Information
Technical Data
Prefabricated In-Plant Office
Prefabricated in-plant offices are a fast and easy solution for creating enclosed areas inside larger structures. While frequently used as office space in manufacturing or industrial settings, these prefabricated structures can also be utilized as break rooms, restrooms, and training classrooms.
Model Group Design
This is a project file with all standard-sized prefabricated offices. You may either select the size that works best and copy it into your project or use the system family types to draw your own.
Model Group Parameters:
-
Standard Widths
-
6', 8', 10', 12', 14', 16', 18', 20'
-
Minimum Width
-
72"
-
Maximum Width
-
240"
-
Standard Depths
-
4', 6', 8', 10', 12'
-
Minimum Depth
-
48"
-
Maximum Depth
-
144"
-
Standard Heights
-
106 1/4"
-
Minimum Height
-
106.25"
-
Maximum Height
-
106.25"
-
SSG Author
-
AWright
-
Model
-
SS
-
Family ID
-
7c34c898-97d8-4102-a7a4-592821bd1d77
Model Group Properties:
-
Depth
-
8' 0" (96")
-
Height
-
9' 3" (111")
-
Width
-
20' 0" (240")
-
sku
-
SS-820
-
BIMobject Category
-
Construction: Modular Space
-
IFC
-
Building Element Proxy
-
ADA Compliant
-
No
-
Has MEP Connectors
-
Yes
-
Keynote
-
13 34 23.13
-
Assembly Code
-
F1010
-
OmniClass
-
23-19 29 11 13
-
Includes Pricing
-
Yes
Floor
- 2"x6" C channel perimeter frame with included forklift slots
- Galvanized steel weather shield covers entire floor assembly
- 2"x4" lumber floor joists spaced 12" OC
- R-11 fiberglass batt insulation
- Floor decking constructed of 3/4" plywood and 1/8" vinyl floor tile
Walls
- 2"x4" nominal lumber wall studs spaced 16" OC
- R-11 fiberglass batt insulation
- Interior wall covered with 1/2" gypsum board with laminated vinyl covering
- Exterior steel siding attached to 1/8" structural sheathing with waterproofing
Ceiling and Roof
- Interior ceiling height is 8'-0"
- Roof framing is made of 2"x4" lumber spaced 16" OC
- R-11 fiberglass batt insulation
- Interior ceiling finished with 1/2" gyspum board
- Exterior roof sheathed with 7/16" plywood covered with 4mm vapor barrier
- Roof covered with 30 gauge galvanized steel
Windows
- Fixed glass picture window
- Double insulated glazing with vinyl perimeter
- Fixed in place with silicone-based sealent
- Sliding windows optional
Exterior Doors
- Sandwich-type doors with aluminum faces, foam interior core, and wood perimeter
- Welded aluminum frame
- Heavy duty metal hingers
- Single fixed tempered glass pane
Interior Lighting
- 4' T8 twin tube
- Acrylic diffuser cover
Electrical Service Panel
- Preqired service panel
- Includes 60-amp main breaker, 15-amp lighting breaker, 20-amp receptacle breaker
- Additional breakers available on request
- Standard service 240/120V, single phase, 60 cycle